Influence of IOP measurement through the wrong eyepiece of the slit lamp on Goldmann applanation tonometry
T Kubota, T Nagata, A Tawara… - European journal of …, 2008 - journals.sagepub.com
… intraocular pressure (IOP) measurements through the wrong eyepiece of the slit lamp may
be a source of error. … Seven skilled observers measured the IOP from seven healthy subjects. …
be a source of error. … Seven skilled observers measured the IOP from seven healthy subjects. …
11.1 Goldmann Applanation Tonometer
JH Shin - Primary Eye Examination: A Comprehensive Guide to …, 2019 - books.google.com
… examiner looks through the eyepiece, the measuring unit is … with IOP measured with a
Goldmann applanation tonometer, … is designed to be fixed on a slit lamp for measurements. The …
Goldmann applanation tonometer, … is designed to be fixed on a slit lamp for measurements. The …
Intraocular pressure and pachymetry
S Mohamed, S Shah - Optometry: Science, Techniques and …, 2009 - books.google.com
… Measurement of IOP using applanation tonometry is based … The tonometer is placed on the
slit lamp with the prism in place. … The patient’s cornea is aligned using an eyepiece, and the …
slit lamp with the prism in place. … The patient’s cornea is aligned using an eyepiece, and the …
[PDF][PDF] A comparative study of intraocular pressure measurement by three tonometers in normal subjects
SK Prabhakar, BS Mahesh… - Nepalese Journal of …, 2013 - pdfs.semanticscholar.org
… Introduction: Contact Goldmann applanation tonometry (GAT… the need for a Slit Lamp
Microscope. The Portable Perkins … Through the eyepiece when a focused and centered target …
Microscope. The Portable Perkins … Through the eyepiece when a focused and centered target …
Basic ophthalmic instruments
WD Furlan - Handbook of Visual Optics, Volume One, 2017 - taylorfrancis.com
… three images that are seen through the eyepiece, as shown in … Goldmann applanation
tonometer The Goldmann tonometer is an accessory to the slit lamp designed to measure the IOP…
tonometer The Goldmann tonometer is an accessory to the slit lamp designed to measure the IOP…
[PDF][PDF] Clinical estimation of intraocular pressure with a non-contact tonometer and Goldman applanation tonometer as a tool for mass screening and its correlation …
A Sood, A Nazir, F Runyal, S Mohiudin… - Global J Med Public …, 2015 - academia.edu
… known that CCT influenced the accuracy of IOP measurements, … Now, patient’s position was
adjusted and eyepiece reticule … and 16 times magnification was adjusted in the slit lamp. The …
adjusted and eyepiece reticule … and 16 times magnification was adjusted in the slit lamp. The …
A New Tonometer System
B Grolman - Clinical and Experimental Optometry, 1973 - Taylor & Francis
… to the movable platform of a slit lamp base which, with joy stick … experience), no significant
error in IOP measurement, due to the … In applanation tonometry, for each 10 mrn Hg of IOP one …
error in IOP measurement, due to the … In applanation tonometry, for each 10 mrn Hg of IOP one …
TONOMETRY-BIOPHYSICAL BASIS, INSTRUMENTS, CLINICAL ASPECTS
GK KRIEGLSTEIN - … Society: Diagnosis and Therapy-held in …, 1980 - books.google.com
… Intraocular pressure in Goldmann applanation tonometry is … into the eyepiece below the
fluorescing semi-circles. Again, this … The influence of body position on IOP as measured by …
fluorescing semi-circles. Again, this … The influence of body position on IOP as measured by …
An exploration of through-the-eye intraocular pressure measurement device
FT Chiu - 2005 - dspace.mit.edu
… In applanation tonometry, the amount of force is measured to minimally … of the effects of
the eyelid on lOP measurements. … point is not located, the consistent systematic error can be …
the eyelid on lOP measurements. … point is not located, the consistent systematic error can be …